Tafel Slope Calculator
A Tafel slope is the rise in overpotential needed to raise the current tenfold, in mV per decade. Paste your data to get it, with the fit drawn so you can check it.
The numbers shown are made up. Paste from Excel or your potentiostat’s export, with potentials in volts. 1 line without two numbers skipped.
Leave at 0 if your data is already iR corrected.
On the same scale as your data. The slope does not need it.
Tafel slope, anodic branch
- R² of the fit
- 1.0000
- Range fitted
- 0.200 to 20.0 mA/cm²
- Apparent transfer coefficient α
- 0.99
- Exchange current density
- 3.0 × 10⁻⁵ mA/cm²
- Overpotential at 10 mA/cm²
- 331 mV
7 points over 2.0 decades
Extrapolated from the fit to the equilibrium potential
The range is a suggestion: the widest stretch that is straight. Check it against your data.
A flat stretch here is a slope worth reporting. If it never goes flat, one number will not describe your data.
The sums run on this page. Nothing you enter or paste is sent anywhere.
The formula
In the Tafel region, η = a + b × log₁₀|j|, where η is the overpotential, j is the current density and b is the Tafel slope. The tool fits this line by least squares over the range you choose. Its slope does not need the equilibrium potential, but the exchange current density and overpotential do.
The apparent transfer coefficient follows from b = 2.303 × R × T ÷ (α × F). At 25 °C, α = 0.5 gives about 118 mV/dec.
Your potentials should be on the scale you report. To move them to RHE, use the potential converter.
Tafel slopes for hydrogen evolution
| Step limiting the rate | Tafel slope |
|---|---|
| Volmer | about 120 mV/dec |
| Heyrovsky | about 40 mV/dec, or 120 mV/dec at high coverage |
| Tafel | about 30 mV/dec |
Values from the microkinetic models of Shinagawa et al., which show that slopes depend on surface coverage.
Getting a slope you can trust
- Correct fully for ohmic resistance.
- Scan slowly, under 5 mV/s, or hold each potential.
- Keep mass transport high, so that the current is not limited by what reaches the electrode.
- Fit at least a decade of current if your data allows, and report the range.
Frequently asked questions
What is a Tafel slope?
It is the rise in overpotential needed to raise the current tenfold, in mV per decade. It comes from the straight part of a plot of potential against log current density, and it says how sharply a reaction speeds up as you push it.
How do I calculate a Tafel slope?
Plot potential against log₁₀ of the current density, and fit a straight line through the linear region. With two points, divide the change in potential by the change in log current: 1.50 V at 1 mA/cm² and 1.56 V at 10 mA/cm² is 60 mV over one decade, so 60 mV/dec.
What does a Tafel slope of 120, 40 or 30 mV/dec mean?
For hydrogen evolution, microkinetic models give about 120, 40 and 30 mV/dec when the Volmer, Heyrovsky and Tafel steps limit the rate. The slope depends on surface coverage, though: the Heyrovsky step can also give 120 mV/dec at high coverage, so a slope alone does not prove a mechanism.
Which range should I fit?
A stretch where the local slope stays constant. Fitting a slightly curved plot in a range picked by eye gives an arbitrary average. The local slope plot under the calculator shows the slope at each potential: a flat region is a slope worth reporting, and not all data has one.
Do I need iR correction?
Yes. Full correction of the ohmic resistance is one of the conditions for a kinetic Tafel slope. At 10 mA through 5 Ω, the uncorrected potential is off by 50 mV. Enter the resistance here, or leave it at 0 if your data is already corrected.
What scan rate should I use for Tafel analysis?
A slow one: van der Heijden et al. advise under 5 mV/s. With good mass transport, they found a linear sweep at 2 mV/s gave a similar slope to chronoamperometry and impedance.
How do I get the exchange current density?
Extend the fitted line to the equilibrium potential. The current density there is the exchange current density. It is only as good as the slope, and a small error in the slope moves it a long way, so treat it as an estimate.
Sources
- van der Heijden et al., Tafel Slope Plot as a Tool to Analyze Electrocatalytic Reactions, ACS Energy Letters 9, 1871 (2024)
- Shinagawa, Garcia-Esparza and Takanabe, Insight on Tafel slopes from a microkinetic analysis of aqueous electrocatalysis for energy conversion, Scientific Reports 5, 13801 (2015)
Use this in your group?
Link to it from your lab’s resources page, or cite it like this:
METNMAT. Tafel Slope Calculator. https://www.metnmat.com/tools/tafel-slope-calculator
For the experiment itself
See working electrodes and reference electrodes, or read how to measure a Tafel slope and how to set up a three-electrode cell.
More free calculators
- Reference Electrode Potential Converter
Convert a potential from Ag/AgCl, SCE, Hg/HgO or Hg/Hg₂SO₄ to RHE and SHE.
- Faradaic Efficiency Calculator
Work out FE for several products at once, from GC, headspace or liquid data.
- ECSA Calculator
Get electrochemically active surface area from double-layer capacitance, or from Hupd or CO stripping on Pt.