Skip to content
Free tool

Tafel Slope Calculator

A Tafel slope is the rise in overpotential needed to raise the current tenfold, in mV per decade. Paste your data to get it, with the fit drawn so you can check it.

The numbers shown are made up. Paste from Excel or your potentiostat’s export, with potentials in volts. 1 line without two numbers skipped.

Leave at 0 if your data is already iR corrected.

On the same scale as your data. The slope does not need it.

Tafel slope, anodic branch

59.9mV/dec
R² of the fit
1.0000
Range fitted
0.200 to 20.0 mA/cm²

7 points over 2.0 decades

Apparent transfer coefficient α
0.99
Exchange current density
3.0 × 10⁻⁵ mA/cm²

Extrapolated from the fit to the equilibrium potential

Overpotential at 10 mA/cm²
331 mV
Tafel plotIn the fitLeft outFitted line
1.451.501.551.601.65012log₁₀ |j| (mA/cm²)E (V)
0.200 mA/cm²
20.0 mA/cm²

The range is a suggestion: the widest stretch that is straight. Check it against your data.

Local Tafel slope
60801001201401.451.501.551.601.65E (V)Slope (mV/dec)

A flat stretch here is a slope worth reporting. If it never goes flat, one number will not describe your data.

The sums run on this page. Nothing you enter or paste is sent anywhere.

The formula

In the Tafel region, η = a + b × log₁₀|j|, where η is the overpotential, j is the current density and b is the Tafel slope. The tool fits this line by least squares over the range you choose. Its slope does not need the equilibrium potential, but the exchange current density and overpotential do.

The apparent transfer coefficient follows from b = 2.303 × R × T ÷ (α × F). At 25 °C, α = 0.5 gives about 118 mV/dec.

Your potentials should be on the scale you report. To move them to RHE, use the potential converter.

Tafel slopes for hydrogen evolution

Tafel slopes when each hydrogen evolution step limits the rate
Step limiting the rateTafel slope
Volmerabout 120 mV/dec
Heyrovskyabout 40 mV/dec, or 120 mV/dec at high coverage
Tafelabout 30 mV/dec

Values from the microkinetic models of Shinagawa et al., which show that slopes depend on surface coverage.

Getting a slope you can trust

  • Correct fully for ohmic resistance.
  • Scan slowly, under 5 mV/s, or hold each potential.
  • Keep mass transport high, so that the current is not limited by what reaches the electrode.
  • Fit at least a decade of current if your data allows, and report the range.

Frequently asked questions

What is a Tafel slope?

It is the rise in overpotential needed to raise the current tenfold, in mV per decade. It comes from the straight part of a plot of potential against log current density, and it says how sharply a reaction speeds up as you push it.

How do I calculate a Tafel slope?

Plot potential against log₁₀ of the current density, and fit a straight line through the linear region. With two points, divide the change in potential by the change in log current: 1.50 V at 1 mA/cm² and 1.56 V at 10 mA/cm² is 60 mV over one decade, so 60 mV/dec.

What does a Tafel slope of 120, 40 or 30 mV/dec mean?

For hydrogen evolution, microkinetic models give about 120, 40 and 30 mV/dec when the Volmer, Heyrovsky and Tafel steps limit the rate. The slope depends on surface coverage, though: the Heyrovsky step can also give 120 mV/dec at high coverage, so a slope alone does not prove a mechanism.

Which range should I fit?

A stretch where the local slope stays constant. Fitting a slightly curved plot in a range picked by eye gives an arbitrary average. The local slope plot under the calculator shows the slope at each potential: a flat region is a slope worth reporting, and not all data has one.

Do I need iR correction?

Yes. Full correction of the ohmic resistance is one of the conditions for a kinetic Tafel slope. At 10 mA through 5 Ω, the uncorrected potential is off by 50 mV. Enter the resistance here, or leave it at 0 if your data is already corrected.

What scan rate should I use for Tafel analysis?

A slow one: van der Heijden et al. advise under 5 mV/s. With good mass transport, they found a linear sweep at 2 mV/s gave a similar slope to chronoamperometry and impedance.

How do I get the exchange current density?

Extend the fitted line to the equilibrium potential. The current density there is the exchange current density. It is only as good as the slope, and a small error in the slope moves it a long way, so treat it as an estimate.

Sources

Use this in your group?

Link to it from your lab’s resources page, or cite it like this:

METNMAT. Tafel Slope Calculator. https://www.metnmat.com/tools/tafel-slope-calculator

For the experiment itself

See working electrodes and reference electrodes, or read how to measure a Tafel slope and how to set up a three-electrode cell.

More free calculators