Faradaic Efficiency Calculator
Faradaic efficiency (FE) is the share of the charge you passed that went into a product: FE = z × F × n ÷ Q. Enter your readings to get FE for every product at once, and the total.
Enter the temperature and pressure the flow rate refers to. For a mass flow controller reading in sccm, use its reference conditions, often 0 °C.
Each gas, as the GC reads it
Total Faradaic efficiency
- H₂13.1%
- CO57.8%
- C₂H₄23.7%
- Total gas flow
- 13.6 µmol/s
- Electron flow
- 1.04 µmol/s
Your results, product by product
| Product | Electrons | FE | Rate (µmol/h) | Partial current (mA) |
|---|---|---|---|---|
| H₂ | 2 | 13.1% | 245 | 13.1 |
| CO | 2 | 57.8% | 1079 | 57.8 |
| C₂H₄ | 12 | 23.7% | 73.6 | 23.7 |
The sums run on this page. Nothing you enter or paste is sent anywhere.
The formula
FE (%) = 100 × z × F × n ÷ Q. Here z is the electrons per molecule of product, F is the Faraday constant (96,485 C/mol), n is the moles of product and Q is the charge passed in coulombs.
For a gas in a flowing stream, use rates instead. The product’s molar flow is its mole fraction times P × V̇ ÷ (R × T) for the whole stream, and the charge per second is the current. The calculator treats gases as ideal.
A worked example
A cell runs at 10 mA, with 20 mL/min of gas leaving it at 25 °C and 1 atm. The GC reads 1,000 ppm H₂. The whole stream carries 13.6 µmol/s of gas, so H₂ is 0.0136 µmol/s. At two electrons per H₂ that takes 2.63 mA, which is 26.3% of the 10 mA.
For a liquid, 5 mM formate in 30 mL of electrolyte is 150 µmol. After 50 C of charge, the Faradaic efficiency for formate is 57.9%.
Electrons per product
| Product | Electrons, z | Reaction |
|---|---|---|
| H₂ | 2 | 2 H⁺ + 2 e⁻ → H₂ |
| CO | 2 | CO₂ + 2 H⁺ + 2 e⁻ → CO + H₂O |
| CH₄ | 8 | CO₂ + 8 H⁺ + 8 e⁻ → CH₄ + 2 H₂O |
| C₂H₄ | 12 | 2 CO₂ + 12 H⁺ + 12 e⁻ → C₂H₄ + 4 H₂O |
| C₂H₆ | 14 | 2 CO₂ + 14 H⁺ + 14 e⁻ → C₂H₆ + 4 H₂O |
| O₂ | 4 | 2 H₂O → O₂ + 4 H⁺ + 4 e⁻ |
| Formate | 2 | CO₂ + H⁺ + 2 e⁻ → HCOO⁻ |
| Methanol | 6 | CO₂ + 6 H⁺ + 6 e⁻ → CH₃OH + H₂O |
| Ethanol | 12 | 2 CO₂ + 12 H⁺ + 12 e⁻ → C₂H₅OH + 3 H₂O |
| Acetate | 8 | 2 CO₂ + 7 H⁺ + 8 e⁻ → CH₃COO⁻ + 2 H₂O |
| n-Propanol | 18 | 3 CO₂ + 18 H⁺ + 18 e⁻ → C₃H₇OH + 5 H₂O |
| NH₃ from nitrate | 8 | NO₃⁻ + 9 H⁺ + 8 e⁻ → NH₃ + 3 H₂O |
| NH₃ from N₂ | 3 | N₂ + 6 H⁺ + 6 e⁻ → 2 NH₃ |
| H₂O₂ from O₂ | 2 | O₂ + 2 H⁺ + 2 e⁻ → H₂O₂ |
N₂ reduction gives two NH₃ for six electrons, so z is 3 for each NH₃. For anything else, choose Other product and type z.
Frequently asked questions
What is Faradaic efficiency?
It is the share of the charge passed through a cell that ends up in a given product. A Faradaic efficiency of 60% for CO means 60% of the electrons went into making CO.
How do I calculate Faradaic efficiency from GC data?
Multiply the gas's mole fraction by the total gas flow in mol/s, then by the electrons per molecule and the Faraday constant, and divide by the current in amps. In the calculator, choose Flowing gas and enter the ppm from your GC, the outlet flow and the current.
Should I use the inlet or the outlet flow rate?
The outlet, measured downstream near the instrument that samples the gas. In CO₂ electrolysis, CO₂ is used up at the electrode and by reaction with hydroxide, so less gas leaves the cell than enters it. Using the inlet flow then overstates the Faradaic efficiency of gas products, most of all at high current in alkaline electrolyte.
Why is my total Faradaic efficiency below 100%?
Look for products that escaped or that you did not measure, product consumed at the counter electrode, and reactions in the solution.
Why is my total Faradaic efficiency above 100%?
Common causes are overestimating the sampled volume, sampling a concentrated product, or product that forms without the current, for example through corrosion.
What do I enter if my flow is in sccm?
Enter the number as mL/min, with the temperature and pressure that your controller's standard refers to. Makers differ, so check the manual. 0 °C and 101.325 kPa is a common choice.
How should I report Faradaic efficiency?
Kempler and Nielander recommend error bars from the standard deviation of at least three separate measurements, because errors from sampling are nearly always larger than the instrument's own error. Report the flow rates too.
Sources
- Kempler and Nielander, Reliable reporting of Faradaic efficiencies for electrocatalysis research, Nature Communications 14, 1158 (2023)
- Ma et al., Insights into the carbon balance for CO₂ electroreduction on Cu using gas diffusion electrode reactor designs, Energy & Environmental Science 13, 977 (2020)
Use this in your group?
Link to it from your lab’s resources page, or cite it like this:
METNMAT. Faradaic Efficiency Calculator. https://www.metnmat.com/tools/faradaic-efficiency-calculator
For the experiment itself
See CO₂ electrolysis cells and water splitting reactors, or read how to calculate Faradaic efficiency and H-cell or flow cell?
More free calculators
- Reference Electrode Potential Converter
Convert a potential from Ag/AgCl, SCE, Hg/HgO or Hg/Hg₂SO₄ to RHE and SHE.
- Tafel Slope Calculator
Paste your polarization data for the Tafel slope, R², exchange current density and overpotential.
- ECSA Calculator
Get electrochemically active surface area from double-layer capacitance, or from Hupd or CO stripping on Pt.