Tafel Slope: Formula, Units and How to Measure It
The Tafel slope is the extra overpotential needed to raise the current tenfold, in mV per decade (mV/dec). It is b in the Tafel equation, η = a + b log₁₀|j|. A lower Tafel slope means the current rises faster as the overpotential grows. Measure it from a slow, iR-corrected polarization curve, plotted as overpotential against the logarithm of current density.
The formula
b = 2.303 RT / (αF), where α is the transfer coefficient. At 25 °C, 2.303 RT/F is 59.2 mV, so α = 0.5 gives about 118 mV/dec.
For hydrogen evolution, the slowest step of the reaction is often read from the Tafel slope. The classic values below assume simple conditions, and real catalysts often fall in between, so treat them as a guide rather than a proof of mechanism.
| Slowest step | Tafel slope |
|---|---|
| Volmer: hydrogen adsorbs on the surface | About 120 mV/dec |
| Heyrovsky: electrochemical desorption | About 40 mV/dec |
| Tafel: two adsorbed hydrogens combine | About 30 mV/dec |
How to measure it
- Record a slow linear sweep, about 1 to 5 mV/s, or hold a series of steady potentials, so that charging current does not add to the result.
- Correct for solution resistance: E(corrected) = E − iR, with R from impedance or current interrupt.
- Convert the potential to overpotential on the RHE scale. The potential converter does the reference electrode part.
- Plot overpotential against log₁₀|j| and fit the straight part, usually one to two decades of current at low overpotential.
- Report the range you fitted, and how much iR correction you applied.
Worked example
If the overpotential needed rises from 300 mV at 1 mA/cm² to 360 mV at 10 mA/cm², the current rose one decade for 60 mV, so the Tafel slope is 60 mV/dec.
Mistakes to avoid
- Skipping iR correction, which makes the slope look larger at high current.
- Fitting the curved region at high current, where bubbles and mass transport limit the current.
- Fast scans, which add capacitive current at low overpotential.
- For nickel-based oxygen evolution catalysts, fitting across the nickel oxidation peak. Use the reverse scan or steady-state points instead.
Frequently asked questions
What is the unit of the Tafel slope?
Millivolts per decade, mV/dec: the overpotential needed for each tenfold rise in current.
Is a lower Tafel slope better?
Usually, for a catalyst, because the current grows faster with overpotential. Compare it together with the overpotential needed at a set current density, such as 10 mA/cm².
How do I make a Tafel plot from an LSV?
Correct the potential for iR, convert it to overpotential, then plot overpotential against log₁₀ of the current density and fit the straight part.