Skip to content
Guide

How to Calculate Faradaic Efficiency

Faradaic efficiency is the share of the charge passed that went into one product: FE = z × n × F / Q, where z is the number of electrons per molecule, n the moles of product, F the Faraday constant (96,485 C/mol) and Q the total charge. For a gas measured by online GC, use FE = z × F × x × ṅ / I, where x is the product's mole fraction in the outlet gas, ṅ the molar gas flow and I the current.

Electrons per product

The only number that changes from product to product is z, the electrons needed to make one molecule. Read it from the balanced half-reaction.

Electrons transferred per molecule of common products
ProductHalf-reactionElectrons (z)
Hydrogen (H₂)2H⁺ + 2e⁻ → H₂2
Carbon monoxide (CO)CO₂ + 2H⁺ + 2e⁻ → CO + H₂O2
Formate (HCOO⁻)CO₂ + H⁺ + 2e⁻ → HCOO⁻2
Methanol (CH₃OH)CO₂ + 6H⁺ + 6e⁻ → CH₃OH + H₂O6
Methane (CH₄)CO₂ + 8H⁺ + 8e⁻ → CH₄ + 2H₂O8
Ethylene (C₂H₄)2CO₂ + 12H⁺ + 12e⁻ → C₂H₄ + 4H₂O12
Ethanol (C₂H₅OH)2CO₂ + 12H⁺ + 12e⁻ → C₂H₅OH + 3H₂O12
Oxygen (O₂), at the anode2H₂O → O₂ + 4H⁺ + 4e⁻4

For a gas product measured by GC

  • Measure the gas flow at the cell outlet, not the inlet. In CO₂ electrolysis some CO₂ turns into carbonate in the electrolyte, so less gas leaves than enters, and the inlet flow overstates the efficiency.
  • Convert the flow to moles per second: ṅ = p × V̇ / (R × T). At 25 °C and 1 atm, one mole of gas fills about 24,465 mL.
  • Take the product's mole fraction x from the calibrated GC. 1,000 ppm is 0.001.
  • Calculate FE = z × F × x × ṅ / I, with I in amperes at the time of the injection.

For a liquid product

  • Measure the concentration after the run, by NMR or HPLC, and multiply by the electrolyte volume to get the moles, n.
  • Take the charge passed during the run, Q, from the potentiostat. At constant current it is the current times the time.
  • Check both chambers. Liquid products such as formate can cross the membrane, and some are oxidised at the anode.
  • Calculate FE = z × n × F / Q.

Worked examples

Hydrogen, collected over a run: 10 mA for one hour passes Q = 0.010 × 3,600 = 36 C. If 0.18 mmol of H₂ is collected, FE = 2 × 0.00018 × 96,485 / 36 = 96.5%.

CO, by online GC: the outlet gas holds 1.00% CO (x = 0.01) and flows at 20 mL/min, measured at 25 °C and 1 atm. Then ṅ = 20 / 60 / 24,465 = 1.362 × 10⁻⁵ mol/s, and at 50 mA, FE = 2 × 96,485 × 0.01 × 1.362 × 10⁻⁵ / 0.050 = 52.6%.

When the efficiencies do not add up to 100%

  • A product was not measured, for example liquids when only the gas was analysed.
  • A product crossed the membrane, or was oxidised at the anode.
  • Gas leaked, or the inlet flow was used where the outlet flow should have been.
  • The current changed while the gas sample was taken, or the GC calibration is out of date.

Frequently asked questions

What is Faradaic efficiency?

The fraction of the charge passed through a cell that made a given product. It is also called Faradaic yield or current efficiency.

How many electrons does CO₂ to CO take?

Two: CO₂ + 2H⁺ + 2e⁻ → CO + H₂O. So z = 2 in the Faradaic efficiency formula.

Why is my Faradaic efficiency above 100%?

Usually because the gas flow in the formula is too high, for example the inlet flow of a cell that loses CO₂ to carbonate, or because the GC calibration has drifted. Measure the flow at the outlet and recheck the calibration.

See also