What Is a Zero-Gap Electrolyzer?

A zero-gap electrolyzer presses the electrodes directly against both sides of the membrane, so there is no layer of liquid electrolyte between them. Ions only have to cross the membrane, which keeps the resistance low and lets the cell run at high current density for a lower voltage. PEM and AEM water electrolyzers are built this way, and so are many CO₂ electrolyzers.

How a zero-gap cell is built

From the outside in, on each side of the membrane:

  • End plates, bolted together, that hold the stack under even pressure.
  • Flow fields: channels that bring in water, electrolyte or gas and carry the products away.
  • Porous transport or gas diffusion layers, such as titanium felt, nickel foam or carbon paper, that spread the flow and conduct current.
  • Catalyst layers, coated on the membrane or on the porous layers.
  • The membrane at the centre, with gaskets around it that set how far the porous layers are compressed.

Zero-gap cell or a cell with a liquid gap

Zero-gap cells compared with flow cells that keep a liquid electrolyte layer
Zero-gap cellCell with a liquid electrolyte gap
Between electrode and membraneNothing: they are pressed togetherA channel of liquid electrolyte
ResistanceLowHigher
Cell voltage at a given currentLowerHigher
Reference electrodeHard to place, so cell voltage is usually reportedCan sit in the liquid layer
Closest toIndustrial electrolyzersLab studies at practical rates

Zero-gap cells for water and CO₂

PEM and AEM water electrolyzers are zero-gap by design: the catalyst layers sit on the membrane, and the cell is fed with water, or with dilute alkali for many AEM cells. Modern alkaline electrolyzers also often press their electrodes against a porous separator.

In a zero-gap CO₂ electrolyzer, humidified CO₂ flows to a gas diffusion cathode pressed against an anion exchange membrane, and an anolyte or water flows past the anode. The usual problems are water balance, CO₂ lost as carbonate through the membrane, and carbonate salts building up in the cathode.

Assembly tips

  • Match the gasket thickness to the porous layers, so that they are compressed by the amount the cell is designed for.
  • Tighten the bolts gradually in a cross pattern to an even torque, so the pressure across the membrane is uniform.
  • Pretreat the membrane as its maker specifies before you build the cell.
  • Leak-test with gas before you add any liquid.
  • Run the cell at a low current for a while before you take measurements, so that it settles.

Frequently asked questions

What does zero gap mean in an electrolyzer?

That there is no liquid gap between the electrodes and the membrane: they are pressed together, so the ions only cross the membrane, which keeps the resistance low.

Is a PEM electrolyzer a zero-gap electrolyzer?

Yes. A PEM electrolyzer is built around a membrane electrode assembly, with the catalyst layers pressed against the membrane.

Why do salts form in a zero-gap CO₂ electrolyzer?

Cations from the anolyte cross the membrane and meet the carbonate formed at the cathode, so carbonate salts can build up in the gas diffusion electrode and block the gas.