How to Pretreat a PFSA Proton Exchange Membrane
The usual pretreatment for a PFSA proton exchange membrane is an hour at about 80 °C in each of four baths: 3% hydrogen peroxide, deionised water, 0.5 M sulfuric acid, and deionised water again. Then keep it wet in deionised water. This removes organic impurities and leaves the membrane fully in its acid form.
The four steps
These are the usual steps for PFSA membranes such as N117, N115 and N212. Labs vary the times and temperatures, and some leave out the peroxide step for a clean new membrane. Where the maker's sheet gives a procedure, follow it.
| Step | Bath | Typical conditions | What it does |
|---|---|---|---|
| 1 | 3% hydrogen peroxide | About 80 °C, 1 hour | Oxidises organic impurities |
| 2 | Deionised water | About 80 °C, 1 hour | Rinses out the peroxide |
| 3 | 0.5 M sulfuric acid | About 80 °C, 1 hour | Swaps any metal ions for protons |
| 4 | Deionised water | About 80 °C, 1 hour, often repeated | Rinses out the excess acid |
Before you start
- Wear gloves and handle the membrane with flat tweezers. It creases easily and picks up dirt from fingers.
- Use clean glass or PTFE containers and only deionised water. The metal ions in tap water take the place of protons and raise the membrane's resistance.
- Allow for swelling. A wet PFSA membrane is larger than a dry one, so cut it with this in mind, or cut it after pretreatment.
- Never let it dry out between steps.
After pretreatment
- Store it wet in deionised water, in a clean closed container, until you use it.
- Avoid drying it and wetting it again: its size changes each time, which makes it harder to seal in a cell.
Anion exchange membranes are different
An anion exchange membrane does not get this acid treatment. It is usually soaked in KOH or NaOH to exchange it to the hydroxide form before use.
In air, a hydroxide-form membrane takes up CO₂ and turns to the carbonate form, so exchange it shortly before use and keep it wet. Times and concentrations differ between makers, so follow the maker's procedure.
Frequently asked questions
Why is a proton exchange membrane treated with hydrogen peroxide?
To oxidise and remove organic impurities left from manufacture and handling.
Why is the membrane heated in sulfuric acid?
To swap any metal ions in the membrane for protons, so that it is fully in its acid form and conducts protons as well as it can.
How should a pretreated membrane be stored?
Wet, in deionised water in a clean closed container, until it is used.